Ensure the walking lane is completely clear of objects, tools, and personnel. Switch on the internal circuit breaker.
Use shims or the integrated leveling feet to adjust the cabinet until it is perfectly level along both the horizontal and vertical axes.
Use a chalk line or laser level to mark the centerlines of the cabinets and the clear walking lane width on the floor.
Once aligned, use a torque wrench to tighten the glass clamps to the final specified torque rating to prevent slippage during operation. 4. Electrical Connections and Wiring gunnebo speedstile fl installation manual
is an automatic speed gate, characterized by its swing panels (glass or polycarbonate) that open quickly in the direction of traffic. Secure, high-throughput access control.
Plug the pre-terminated connectors into the matching RJ45 or terminal block ports on the central logic controller board.
is a straightforward process when following the manufacturer’s instructions, but it requires precision for optimal operation. By ensuring a proper foundation, careful alignment, and correct electrical installation, you will secure the longevity and performance of your entrance control system. Ensure the walking lane is completely clear of
The glass wings are not pre-attached for shipping safety.
Place an obstruction in the path of the closing wings to verify that the torque-sensing safety reverse mechanism functions immediately. 6. Troubleshooting Common Installation Errors Potential Cause Resolution Wings scrape or misalign when closing Cabinets are not level or parallel Loosen anchor bolts, re-shim the base, and re-torque. Tailgating alarm triggers constantly Misaligned or dirty IR sensors Realign internal sensor strips; clean lenses. Access reader grants access, but wings do not open Incorrect wiring configuration
Enter the lane from the exit side while it is open for an authorized entry. Use a chalk line or laser level to
Check the alignment of the infrared photocell beams along the inside of the cabinets. Clean the lenses with a microfiber cloth. If a beam is misaligned, the control board will trigger a continuous fault code. Safety Testing:
Verify reader relay is connected to "Dry Contact" input, not voltage output. "Fire Alarm" error on control board Open circuit on emergency loop
(Fast Lane) is a premium speed gate designed to meet these needs, offering a sleek, user-friendly, and secure entrance control solution.
Check the diagnostic LEDs on the sensor receiver strips inside the lane walls. A solid green LED indicates perfect beam alignment.